RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-69
11. Align the external power meter to the reference power meter by typing the OCM FIPS
command: a 71 1 xxx; where “xxx” is the reading of the reference power meter and “1”
indicates the external power meter. Calibration may take up to two minutes to complete.
Note: If the calibration factor is not within the range of 0.8 and 1.2 or the system didn’t calibrate,
repeat this step up to three times. If the system still doesn’t calibrate or the cal factor is still out
of range, replace the detector or coupler as needed. (The difference between the average value
read and the reference power meter was greater than 20% and the system was not able to
compensate.)
RFO FIPS: a 71 1 201
Please wait. Command in process...
RA 71
<<< CALIBRATE DETECTORS >>>
========= Detector 1 Calibration =========
0x10: 0x44 0x45 0x54 0x31 "DET1"
0x11: 0x30 0x32 0x30 0x31 "0201"
0x12: 0x32 0x2e 0x34 0x39 "2.49"
0x13: 0x36 0x36 0x39 0x32 "6692"
0x14: 0x44 0x45 0x54 0x31 "DET1"
0x15: 0x44 0x45 0x54 0x31 "DET1"
0x16: 0x44 0x45 0x54 0x31 "DET1"
0x17: 0x44 0x45 0x54 0x31 "DET1"
0x18: 0x44 0x45 0x54 0x31 "DET1"
0x19: 0x44 0x45 0x54 0x31 "DET1"
0x1a: 0x44 0x45 0x54 0x31 "DET1"
0x1b: 0x44 0x45 0x54 0x31 "DET1"
0x1c: 0x31 0x2e 0x32 0x2e "1.2."
0x1d: 0x33 0x20 0x00 0x00 "3 .."
0x1e: 0x30 0x30 0x30 0x30 "0000"
0x1f: 0x43 0x48 0x4b 0xb7 "CHK."
0x3f: 0x43 0x48 0x4b 0xf8 "CHK."
Calibration Factor = 0.936122
=============================================