User Manual

Table Of Contents
Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-68 6880493G02-C July 2000
10. Wait two minutes for transmitter to key up 60 times, and stabilize at the new power setting. Verify
that the external calibration factor is 1.00000 by typing the RFO FIPS command: a 79 2.
Also verify that the uncalibrated external wattmeter reading is within 20% of the reading
on the reference power meter. Use the “Power Per Subchannel” reading from the a 79 2
response as the external wattmeter reading.
RFO FIPS: a 79 2
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= EXTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 201 Watts
Total Wattmeter Voltage: +2.51 Volts
Average FM Keyed Readings (over last 20 keyups):
Power Per Subchannel: 201 Watts <----------------Use this reading
Calibration Factor: 1.000000
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================