8. Key the transmitter in test mode with following FIPS command: a 176 0 8 0 0 0 1 10 5 1
9. Increase post-cavity power to 200 Watts by adjusting the OCM parameter 990 starting with initial
value of 0.5 (i.e. FIPS: w 990 0.5). Note that the range of parameter 990 is 0.0 to 1.0. Make initial
steps of 0.1. The external power meter must be calibrated between 195 and 205 watts ± 5
watts.
RFO FIPS: a 176 0 8 0 0 0 1 10 5 1
RFO FIPS: RA 176
<<< RFO TEST MODES >>>
Using Default Frequency Offsets of 1 15 2 14.
Where:
13 = -18.75 kHz, 14 = -12.50 kHz, 15 = -6.25 kHz
0 = 0.00 kHz
1 = 6.25 kHz, 2 = 12.50 kHz, 3 = 18.75 kHz
(Use Command "A 195" to modify the Frequency Offsets).
Using Default Channel Setting of 0.
(Use Command "A 196" to modify the Channel Setting).
The Station is Keyed in Test Mode.
RFO FIPS: r 990
RFO FIPS: RR 990 0.408269
RFO FIPS: w 990 0.50
RFO FIPS: RW 990 0.500000
RFO FIPS: w 990 0.55
RFO FIPS: RW 990 0.550000
RFO FIPS: w 990 .56
RFO FIPS: RW 990 0.560000
RFO FIPS: w 990 .561
RFO FIPS: RW 990 0.561000