User Manual

Table Of Contents
Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-64 6880493G02-C July 2000
17. Wait two minutes for the transmitter to key up at least 60 times. Read internal wattmeter
readings using the RFO FIPS commands: a 79 0 and a 79 1. Verify that the reference
power meter and the internal forward power meter are within 10% of each other.
RFO FIPS: a 79 0
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= INTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 101 Watts
Total Wattmeter Voltage: +1.09 Volts
Average FM Keyed Readings (over last 20 keyups):
Power Per Subchannel: 100 Watts
Calibration Factor: 1.188193
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================
RFO FIPS: a 79 1
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= INTERNAL REFLECTED WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 0 Watts
Total Wattmeter Voltage: +0.00 Volts
Average FM Keyed Readings (over last 20 keyups):
Power Per Subchannel: 0 Watts
Calibration Factor: 1.188193
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================