User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-63
15. Initialize amplitude alignment parameters with the FIPS command: a 75
16. Key the transmitter in test mode with following FIPS command: a 176 0 8 0 0 0 1 10 5 1
RFO FIPS: a 75
RFO FIPS: RA 75
<<< ALIGNMENT PARAMETER DEFAULT VALUES >>>
K-Factor 990 = 0.408269
Fdback Atten 996 = 255
Phase Trng 982 = -10000
Txlin Reg2 954 = 84
Txlin Reg1 953 = 14
Txlin Atten 974 = 0
Mod Dev 2053 = 4800
FM Power Lvl 2054 = 28000
AM Pilot Pwr 2055 = 1600
AM Sdbd Pwr 2056 = 12426
=============================================
RFO FIPS: a 176 0 8 0 0 0 1 10 5 1
RFO FIPS: RA 176
<<< RFO TEST MODES >>>
Using Default Frequency Offsets of 1 15 2 14.
Where:
13 = -18.75 kHz, 14 = -12.50 kHz, 15 = -6.25 kHz
0 = 0.00 kHz
1 = 6.25 kHz, 2 = 12.50 kHz, 3 = 18.75 kHz
(Use Command "A 195" to modify the Frequency Offsets).
Using Default Channel Setting of 0.
(Use Command "A 196" to modify the Channel Setting).
The Station is Keyed in Test Mode.