Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-62 6880493G02-C July 2000
Note: If the calibration factor is not within the range of 0.8 and 1.2 or the system didn’t calibrate (no
table returned), repeat Step 11 up to three times. If the system still does not calibrate or the cal
factor is still out of range, replace the detector or coupler as needed. (In the example given, the
difference between the average value read and the reference power meter was greater than 20%
and the system was not able to compensate.)
12. Turn off the OCM test mode (dekey) using the FIPS command: a 177
13. The RF-O! internal power meter calibration will take effect on return from reset. Reset the OCM
to have calibration take effect using the RFO FIPS command: a 117
14. Turn off power-control with the RFO FIPS command: w 992 0
RFO FIPS: a 177
RFO FIPS: RA 177
The Station is Dekeyed.
RFO FIPS:
RFO FIPS: a 117
>>>>>>> MOTOROLA RF-ORCHESTRA! <<<<<<<
>>>>>>> WIRELESS MESSAGING SYSTEM (WMS) <<<<<<<
>>>>>>> (c) Copyright 1998 Motorola, Inc. <<<<<<<
>>>>>>> All Rights Reserved. <<<<<<<
>>>>>>> PARAMETER DATABASE UNCHANGED <<<<<<<
ENTER PROTOCOL
fips
ENTER PASSWORD
6000
RFO FIPS: w 992 0
RFO FIPS: RW 992 0