RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-61
11. Align the internal power meter to the reference power meter by sending the RFO FIPS
command: a 71 0 xxx; where “xxx” is the reading of the reference power meter and “0”
indicates the internal power meter. Calibration may take up to two minutes to complete.
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================
RFO FIPS: a 71 0 200
Please wait. Command in process...
RA 71
<<< CALIBRATE DETECTORS >>>
========= Detector 0 Calibration =========
0x00: 0x44 0x45 0x54 0x30 "DET0"
0x01: 0x30 0x32 0x30 0x30 "0200"
0x02: 0x32 0x2e 0x31 0x35 "2.15"
0x03: 0x37 0x39 0x38 0x35 "7985"
0x04: 0x44 0x45 0x54 0x30 "DET0"
0x05: 0x44 0x45 0x54 0x30 "DET0"
0x06: 0x44 0x45 0x54 0x30 "DET0"
0x07: 0x44 0x45 0x54 0x30 "DET0"
0x08: 0x44 0x45 0x54 0x30 "DET0"
0x09: 0x44 0x45 0x54 0x30 "DET0"
0x0a: 0x44 0x45 0x54 0x30 "DET0"
0x0b: 0x44 0x45 0x54 0x30 "DET0"
0x0c: 0x31 0x2e 0x32 0x2e "1.2."
0x0d: 0x33 0x20 0x00 0x00 "3 .."
0x0e: 0x30 0x30 0x30 0x30 "0000"
0x0f: 0x43 0x48 0x4b 0xac "CHK."
0x3f: 0x43 0x48 0x4b 0xea "CHK."
Calibration Factor = 1.188193
=============================================