User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-51
During power up, the user will see the normal RF-O! transmitter banner along with a message
of what has happened to the parameter database. The five possibilities are:
1. No DIP switches are ON, and it is not a cutover. The parameter database is unchanged.
The user will see:
2. The user has set the DIP2 switch ON and reset the station.
3. The user has installed new software (post-RFO_1.1.3) and an automatic cutover is being
performed. The user can also perform a cutover manually. The manual cutover steps are:
a. Write the Active Flash Bank Parameter (901) to the opposite bank.
b. Write the Active Flash Bank Mirror (709) to the opposite bank.
c. Write the Cutover Requested Parameter (940) to request cutover.
d. Clear alarms.
e. Clear error logs.
f. Reset the station.
Example:
>>>>>>> MOTOROLA RF-ORCHESTRA! <<<<<<<
>>>>>>> WIRELESS MESSAGING SYSTEM (WMS) <<<<<<<
>>>>>>> (c) Copyright 1999 Motorola, Inc. <<<<<<<
>>>>>>> All Rights Reserved. <<<<<<<
>>>>>>> PARAMETER DATABASE UNCHANGED <<<<<<<
>>>>>>> WIRELESS MESSAGING SYSTEM (WMS) <<<<<<<
>>>>>>> (c) Copyright 1999 Motorola, Inc. <<<<<<<
>>>>>>> All Rights Reserved. <<<<<<<
>>>>>>> SITE CRITICAL PARAMETERS PRESERVED <<<<<<<
>>>>>>> --FACTORY PRESETS PRESERVED-- <<<<<<<
>>>>>>> ALL OTHER PARAMETERS SET TO DEFAULTS <<<<<<<
RFO FIPS: w 901 x (x = 1 for Bank A, 2 for Bank B)
RFO FIPS: w 709 x (x = 1 for Bank A, 2 for Bank B)
RFO FIPS: w 940 0 (0 = cutover requested)
RFO FIPS: a 103 (clear alarms)