User Manual

Table Of Contents
Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-40 6880493G02-C July 2000
3. While supporting the detector, remove and save the four #T15 TORX
mounting screws.
4. Remove the detector.
Wattmeter (Power Detector) Installation
Perform the following procedure to install the external or internal wattmeter power detector:
1. Verify the kit received is model PTLN1445A RFO DETECTOR and contains the following
parts:
(1) DETECTOR AMP RF NUC-O, Motorola part number 0180503R06
(4) SCRTPG TT3.5X0.6X8, Motorola part number 0310943J15
2. Visually inspect the new detector.
3. Align the detector mounting holes with the chassis holes and install the four mounting
screws (see paragraph, "Wattmeter (Power Detector) Removal", Step 3).
4. Attach the two SMA connectors as labeled and tighten them with a 5/16-inch wrench.
5. Attach the DB9 connector and tighten the two screws.
Note: After replacement of a power detector, Wattmeter Calibration must be performed.
Battery Removal
CAUTION
The 6-hour battery assembly weighs 40 lbs. One person must support the battery
assembly while the another person removes the screws to prevent injury to personnel
and/or damage to the equipment.