Check Power Supplies
Use the following command to diagnose PA power supply problems:
RFO FIPS: a 69 #v C #x #y #z
Figure 6-3: Sample PA Power Supply Diagnostic Output
Table 6-6: Variables for Checking Power Supplies
Variable Description
#v PA number (1 or 2)
#x
modulation mode
0 = none,
1 = FM only
2 = FM and AM (requires live pages)
3 = AM only
#y
number of times you wish to read
#z
number of seconds between reads
RFO FIPS: a 69 2 c 0 1 0
RFO FIPS: RA 69
<<< READ PA DECK 02 A/D 02 >>>
Reg 00: 28 Vref = 195 =>28.60 Volt(s)
Reg 01: 15 Vref = 199 =>15.21 Volt(s)
Reg 02: PA Temp = 207 =>28.53 Deg(s) C
Reg 03: Phase = 000 => 0.00 Volt(s)
Reg 04: Atten = 152 => 2.96 Volt(s)
Reg 05: N/A = 000
Reg 06: N/A = 000
Reg 07: N/A = 000
Reg 08: N/A = 000
Reg 09: N/A = 000
Reg 0A: N/A = 000
Reg 0B: A/D Test = 128 => PASS (> 126)
=========================================