6-18 6880493G02-C July 2000
Figure 6-1: Typical PA A/D Values for One-PA Station (FM)
Note: Data shown for transmitter operating near 25 deg C ambient. The PA will draw higher
currents at higher ambient temperatures.
The following illustration (See Figure 6-3) shows typical PA A/D readings for a 2-PA
configuration (PT 1054) set at 75 Watts by subchannel.
RFO FIPS: a 68 1 c 0 1 0
RFO FIPS: RA 68
<<< READ PA DECK 01 A/D 01 >>>
Reg 00: PDPA = 077 => 0.11 Amp(s)
Reg 01: DPA = 096 => 2.73 Amp(s)
Reg 02: OD = 032 =>14.50 Watt(s)
Reg 03: FPA 1 A = 099 => 2.53 Amp(s)
Reg 04: FPA 1 B = 097 => 2.92 Amp(s)
Reg 05: FPA 2 A = 088 => 2.14 Amp(s)
Reg 06: FPA 2 B = 093 => 2.53 Amp(s)
Reg 07: FPA 3 A = 091 => 2.53 Amp(s)
Reg 08: FPA 3 B = 095 => 2.92 Amp(s)
Reg 09: Fwd = 068 =>78.6 Watt(s)
Reg 0A: Rfltd = 003 => 0.43 Watt(s)
Reg 0B: A/D Test = 128 => PASS (> 127)
=========================================
Check hex value
for $85 +/-20
Check hex value
for $32 +/-6
DPA and FPA current should be
approximately 2.0 to 3.2 A.
Check hex value
for $67 +/- 8
Check for less than 3.2 W
Hex