Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-10 6880493G02-C July 2000
Check the 1PPS search window size (RFO FIPS: r 902). If the window size is not the
default value (5), erase the error log (RFO FIPS: a 111), set the window size to 5 (RFO
FIPS: w 902 5), then check the error log after 1 minute.
If the E_1PPS_INITIAL_SEARCH_FAILURE is in the error log again, you should also
check the RF-B! transmitter controller for the E_1PPS_INITIAL_SEARCH_FAILURE.
Power Cutback LED is Blinking
When the Power Cutback LED is blinking, this indicates that the RF-O! transmitter is disabled
(shutdown). When disabled the RF-O! transmitter will not key (even with test modes). Use
RFO FIPS: a 83 to determine why the transmitter is disabled. Check for any of the PAGING
DISABLE STATUS sources being ACTIVE. Also, use RFO FIPS: a 104 and a99to determine the
reason the transmitter is disabled.
If the RF-B! transmitter controller was recently reset, it is very likely that the External 1 PPS
signal has not been acquired (See a83example above). The External 1 PPS disable should clear
within 10 minutes, as long as the GPS receiver eventually locks.
RFO FIPS: a 83
RFO FIPS: RA 83
<<< STATION STATUS/MODE >>>
Power Control (R 992)..........ENABLED Power Leveling (R 2999)........ 0.00dB
Int Wattmeter Calibration......VALID Ext Wattmeter Calibration......VALID
Amplitude Alignment............VALID
POWER CUTBACK STATE.........SHUTDOWN
PA Temperature............FULL_POWER Ambient Temperature.......FULL_POWER
PA Deck/Power Supply......FULL_POWER Disabled Status.............SHUTDOWN
PAGING DISABLED STATUS (R 100 = 0 = 0h)
Paging Access Disabled (R 99)..OK Power Supply A/D Read..........OK
OCM Ambient Temperature........OK Exciter Synthesizer Lock.......OK
Txlin Local Oscillator Lock....OK AM Clipping....................OK
FM Clipping....................OK PA A/D SPI Read................OK
PA Current.....................OK 28 Volt Reference..............OK
14 Volt Reference..............OK UHSO Present/Operating.........OK
Pendulum Lock..................OK Pendulum Present...............OK
Exciter SPI Read...............OK Circulator Load Thermal Limit..OK
PA Failure.....................OK PA Temperature.................OK
Amplitude Alignment............OK Power Leveling Failure.........OK
Internal Wattmeter VSWR........OK High Int WM Reflected Power....OK
External Wattmeter VSWR........OK High Ext WM Reflected Power....OK
External 1PPS Signal...........ACTIVE RFB REQ Line Down..............OK
PNP Error......................OK PNP Check Error................OK