User Manual

Table Of Contents
Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-4 6880493G02-C July 2000
Verify Data from the RF-B! Transmitter Controller
If the RF-O! transmitter is not transmitting, verify that the RF-B! transmitter controller is
working properly. Refer to the RF-B! Transmitter Controller for the RF-O! Paging Station
Installation and Operation manual for information about the transmitter controller.
RF-O! Transmitter Status
1. Establish an RFO FIPS session.
2. Display the current status of the station with RFO FIPS: a 83. This command displays
the current status of Power Control, Amplitude Alignment, Internal and External
Wattmeter Calibration, Power Cutback State, Paging Disabled Status, and Power
Leveling.
If the Amplitude Alignment or either of the Internal or External Wattmeter Calibrations are
INVALID, the RF-O! transmitter must be aligned or calibrated.
RFO FIPS: a 83
RFO FIPS: RA 83
<<< STATION STATUS/MODE >>>
Power Control (R 992)..........ENABLED Power Leveling (R 2999)........ 0.00dB
Int Wattmeter Calibration......VALID Ext Wattmeter Calibration......VALID
Amplitude Alignment............VALID
POWER CUTBACK STATE.........SHUTDOWN
PA Temperature............FULL_POWER Ambient Temperature.......FULL_POWER
PA Deck/Power Supply......FULL_POWER Disabled Status.............SHUTDOWN
PAGING DISABLED STATUS (R 100 = 0 = 0h)
Paging Access Disabled (R 99)..OK Power Supply A/D Read..........OK
OCM Ambient Temperature........OK Exciter Synthesizer Lock.......OK
Txlin Local Oscillator Lock....OK AM Clipping....................OK
FM Clipping....................OK PA A/D SPI Read................OK
PA Current.....................OK 28 Volt Reference..............OK
14 Volt Reference..............OK UHSO Present/Operating.........OK
Pendulum Lock..................OK Pendulum Present...............OK
Exciter SPI Read...............OK Circulator Load Thermal Limit..OK
PA Failure.....................OK PA Temperature.................OK
Amplitude Alignment............OK Power Leveling Failure.........OK
Internal Wattmeter VSWR........OK High Int WM Reflected Power....OK
External Wattmeter VSWR........OK High Ext WM Reflected Power....OK
External 1PPS Signal...........ACTIVE RFB REQ Line Down..............OK
PNP Error......................OK PNP Check Error................OK