User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-3
Check Front Panel Indications
Table 6-1 provides information about front panel indications, possible failures, and corrective
actions. (LEDs are listed as they appear on the front panel from left to right.)
Table 6-1: RF-Orchestra! Front Panel Indications Troubleshooting Chart
LED Color Status Condition
CONTROL ON Green
On
Control module is ON and has successfully gone through boot
process
Off
Control module is OFF or has not successfully gone through
boot process
CONTROL FAIL Red
On Control module has not successfully gone through boot process
Off Control module has successfully gone through boot process
DISABLE Red
On
The transmitter is disabled. Paging has ceased. Check station
status (A83) and Alarm log (A99) to determine cause of disable.
Off Normal operation
ALARM Red
On
Station alarm has been detected. There is an active alarm in the
A 99 log. Clear this log with A 103.
Off Normal operation
PA KEYED Green
On Station Keyed
Off Station Dekeyed
EXCITER LOCKED Green
On Station locked on transmit frequency
Off One or both exciter synthesizers or Tranlin LO not locked
FULL POWER Green
On Station operating without any cutbacks
Off
Station is operating with a cutback or is shutdown. Check station
status (A 83).
POWER
CUTBACK
Yellow
On
Any PA not at full power (Cutback). Check station status (A83)to
determine the reason for the cutback.
Blinking
Transmitter is Disabled (Shutdown). Check station status (A 83)
and alarm log (A 99).
Off All PAs capable of transmitting at full power