User Manual

Table Of Contents
Operation RF-Orchestra!™ Transmitter Installation and Operation
5-20 6880493G02-C July 2000
Figure 5-10: Internal Reflected Wattmeter Reading
Note: The internal (precavity) reflected power should not be more than five percent of the internal
forward power.
13. Verify the external (postcavity) forward power is sufficient. At the prompt, type:
a 79 2 <Enter>
The system displays the FM power output readings.
Figure 5-11: External Forward Wattmeter Reading
RFO FIPS: a 79 1
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= INTERNAL REFLECTED WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 0 Watts
Total Wattmeter Voltage: +0.00 Volts
Calibration Factor: 1.088330
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================
RFO FIPS: a 79 2
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= EXTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 64 Watts
Total Wattmeter Voltage: +0.70 Volts
Calibration Factor: 1.060201
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================