User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Operation
July 2000 6880493G02-C 5-19
11. Verify that the internal (precavity) forward power is sufficient. At the prompt type:
a790 <Enter>
The system responds with FM power output readings.
Note: The following readings are shown for example only. Your readings may be different.
Figure 5-9: Internal Forward Wattmeter Reading
12. Verify that the internal (precavity) reflected power is not too high (typically, 0 to 3 W
reflected for every 100 W forward is acceptable). At the prompt type:
a 79 1 <Enter>
The system responds with the internal reflected wattmeter readings displayed.
RFO FIPS: a 79 0
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= INTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 79 Watts
Total Wattmeter Voltage: +0.93 Volts
Calibration Factor: 1.088330
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================