User Manual

Table Of Contents
Operation RF-Orchestra!™ Transmitter Installation and Operation
5-18 6880493G02-C July 2000
The service terminal displays the set test channel
Figure 5-6: Set Test Channel Example
9. To set the subchannel frequency offsets, at the prompt type:
a 195 1 2 3 0 <Enter>
The service terminal displays the RF-O! transmitter set subchannel frequency offsets.
Figure 5-7: Set Subchannel Frequency Offsets Example
10. At the prompt type:
a1760800011051 <Enter>
The service terminal displays the RF-O! transmitter test modes:
Figure 5-8: RF-O! Transmitter Test Modes
Note: The RF-O! front panel PA Keyed LED will light. For improved output power stability, allow
the transmitter to warm up for at least three minutes before making any power measurements.
RFO FIPS: a 196 0
RFO FIPS: RA 196
<<< SET TEST CHANNEL >>>
Test Channel Set to 0.
RFO FIPS: a 195 1 2 3 0
RFO FIPS: RA 195 1 2 3 0
<<< SET SUBCHANNEL FREQUENCY OFFSETS >>>
Subchannel Frequency Offsets Set to: 1, 2, 3, 0
For Subchannels 1 Through 4, Respectively.
Where:
13 = -18.75 kHz, 14 = -12.50 kHz, 15 = -6.25 kHz
0 = 0.00 kHz
1 = 6.25 kHz, 2 = 12.50 kHz, 3 = 18.75 kHz
RFO FIPS: a 176 0 8 0 0 0 1 10 5 1
RFO FIPS: RA 176
<<< RFO TEST MODES >>>
Normal Operation is Disabled.
RFO Test Mode is Enabled.
The Station is Keyed...