User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Operation
July 2000 6880493G02-C 5-17
Figure 5-5: RF-O! FIPS Station Status
Note: Verify that the antenna return loss is adequate for transmission. Before proceeding, check that
the antenna is properly fastened to the top of the paging station and that you have the output
power specifications set by the factory.
8. To set the test frequency to the frequency programmed in parameter 2000, at the prompt,
type:
a 196 0 <Enter>
RFO FIPS: a 83
RFO FIPS: RA 83
<<< STATION STATUS/MODE >>>
Power Control (R 992)..........ENABLED Power Leveling (R 2999)........ 0.00dB
Int Wattmeter Calibration......VALID Ext Wattmeter Calibration......VALID
Amplitude Alignment............VALID
POWER CUTBACK STATE.........SHUTDOWN
PA Temperature............FULL_POWER Ambient Temperature.......FULL_POWER
PA Deck/Power Supply......FULL_POWER Disabled Status.............SHUTDOWN
PAGING DISABLED STATUS (R 100 = 0 = 0h)
Paging Access Disabled (R 99)..OK Power Supply A/D Read..........OK
OCM Ambient Temperature........OK Exciter Synthesizer Lock.......OK
Txlin Local Oscillator Lock....OK AM Clipping....................OK
FM Clipping....................OK PA A/D SPI Read................OK
PA Current.....................OK 28 Volt Reference..............OK
14 Volt Reference..............OK UHSO Present/Operating.........OK
Pendulum Lock..................OK Pendulum Present...............OK
Exciter SPI Read...............OK Circulator Load Thermal Limit..OK
PA Failure.....................OK PA Temperature.................OK
Amplitude Alignment............OK Power Leveling Failure.........OK
Internal Wattmeter VSWR........OK High Int WM Reflected Power....OK
External Wattmeter VSWR........OK High Ext WM Reflected Power....OK
External 1PPS Signal...........ACTIVE RFB REQ Line Down..............OK
PNP Error......................OK PNP Check Error................OK