User Manual

Table Of Contents
Operation RF-Orchestra!™ Transmitter Installation and Operation
5-10 6880493G02-C July 2000
4. To start the test, type the following command:
a 176 [options] <Enter>
The test transmission starts immediately. The options specified in the 176 action
command determine the contents of the test message. For example, type a176080001
10 5 1
for 1 subchannel of pulsing random 4-level FM, 6400 bps.
5. End the test by entering the following FIPS command:
a 177 <Enter>
Note: For further details on the a 176 and a 177 action commands, see the FIPS action command
description in Appendix D.
6. Ensure that the distribution network is reconnected, so normal processing can resume.
The test transmission ends immediately, and normal processing resumes.