Reset and Initialization
The RF-O! transmitter operation has three types of resets:
Power-on reset: occurs when power to the RF-O! transmitter controller is interrupted
Hard reset: occurs when the reset button on the RF-O! transmitter is pressed
Software reset: occurs when FIPS action command a 117 is issued or initiated by the
software watchdog
All RF-O! transmitter resets are functionally equal and perform the following actions:
RF-O! transmitter control software boot
FIPS initialization
DSP initialization
I/O initialization
FPGA initialization
Parameter database initialization
Hardware polling
After the RF-O! transmitter software boot, the reset banner is displayed on the service
terminal screen (if connected) as shown in Figure 5-3.
Figure 5-3: Reset Banner
At this point in the reset cycle, FIPS communication with the RF-O! transmitter is available. A
complete reset takes approximately one minute. If DIP switches on switch SW500 are enabled
during reset, the software parameter database reinitializes to default values during the
software boot (Chapter 6, "Maintenance").
>>>>>>> MOTOROLA RF-ORCHESTRA! <<<<<<<
>>>>>>> WIRELESS MESSAGING SYSTEM (WMS) <<<<<<<
>>>>>>> (c) Copyright 1999 Motorola, Inc. <<<<<<<
>>>>>>> All Rights Reserved. <<<<<<<
>>>>>>> PARAMETER DATABASE UNCHANGED <<<<<<<