User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Operation
July 2000 6880493G02-C 5-3
FIPS Commands
FIPS commands are used to control the RF-O! transmitter and are organized in three
categories:
Action commands
Read parameter commands
Write parameter commands
Table 5-2 shows the FIPS command syntax.
Action Commands
An action command causes the RF-O! transmitter to change operating modes or interact with
an external entity. An action command can write one or more parameters to the internal
Orchestra Control Module (OCM) memory or perform a series of functions. The action
command appears in the following format:
a [command #] [parameter or list] <Enter>
Note: Not all action commands have parameters or lists.
Table 5-2: Commands Table
Command
1
1. Some action commands may not need an argument; other commands may use more than one argument.
Designator Description
Action Command
a XXX YYY <Enter>
a
2
XXX
YYY
<Enter>
2. May be upper or lower case.
An action command
The numerical value of action parameter
An action argument
Pressing the
<Enter> key performs an action
Parameter Read
r XXX <Enter>
r
2
XXX
<Enter>
Read from memory command
Numerical value of parameter to be read
Pressing the
<Enter> key performs an action
Parameter Write:
w XXX YYY <Enter>
w
2
XXX
YYY
<Enter>
Write to memory command
The numerical value of a parameter to be changed
Argument to be written
Pressing the
<Enter> key performs an action