User Manual

Table Of Contents
Operation RF-Orchestra!™ Transmitter Installation and Operation
5-2 6880493G02-C July 2000
2. Power up the service terminal.
3. Set the flow control to none.
4. Set up the terminal communication parameters (see Table 5-1).
Note: Keyboard conventions are described in Table 1-1)
5. At the prompt, type: <Enter>
The service terminal displays:
ENTER PROTOCOL:
6. At the prompt, type: FIPS <Enter>
The service terminal displays:
ENTER PASSWORD:
Note: The default password set at the factory is 6000.
7. At the prompt, type: [password] <Enter>
The service terminal displays:
RFO FIPS:
You are now connected to FIPS and ready to perform action, read, and write commands.
Note: The RF-O! FIPS session will time out with inactivity. To access the transmitter again, repeat
Step 5 through Step 7.
Table 5-1: Service Terminal Interface Parameters
Description Setting
Baud rate 9600 (Default Value)
Parity rate None
Data bits 8
Stop bits 1
Emulation VT100