User`s manual

www.vtiinstruments.com
Appendix A: System Configurator 63
The parallel port, the final component in the example system, can now be added. Add the port by
selecting Add Parallel IO Port in the Add menu. Enter “ParallelPort_1” for the name, then enter
“6” in the Number of drive lines text field. Note that, when selected, the System Configurator did
not assign the component to the desired drive line (K1_37 rather than K1_42). Change this by
selecting “K1_42” from the First drive line drop menu.
F
IGURE A-19: PARALLEL PORT DETAIL PANE
This completes the example system. Save the configuration by selecting Save from the File menu
to save, then save the file to a local computer. To export the configuration to the instrument, enter
the EX7000’s IP address in the Address bar and click the Connect button. Once connected, select
Set as current configuration from the Target menu.
A text report of the configuration can be viewed by clicking on the Reports menu and selecting
Configuration Summary. The report will appear below the detail pane of the selected
component. The viewing area of the report can be modified by clicking on the separator bar and
increasing or decreasing the size of the report pane.
F
IGURE A-20: CONFIGURATION SUMMARY REPORT