User's Manual

SYSTem Subsystem
3–118
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
SYSTem:COMMunicate:SERial:PACE
SYSTem:COMMunicate:SERial:PACE?
Sets or queries whether software flow control (pacing) is enabled for the RS-232
port. This command sets both the transmit and receive values.
Avoid using XON pacing when transferring binary data.
  ! 
 
<Flow Control> Query response
NONE
XON
NONE
XON
Not Applicable
–224, “Illegal Parameter Value”
You attempted to set the flow control to an illegal value.
None
Command:  
Query: 
Response: 
All SYSTem:COMMunicate:SERial commands
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples