Specifications

– 8 –
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS
LUBRICATION
All valves and thermostats must be checked and
lubricated periodically. Contact your Vulcan-Hart
authorized servicer.
MAINTENANCE
Contact personnel qualified to install and repair gas
equipment for all other maintenance.
TROUBLESHOOTING
PROBLEM PROBABLE CAUSES
Pilot outage Pilot flame too low.
Restriction in pilot orifice.
Restriction in pilot valve.
Improper burner combustion Improper ventilation.
Poor Ignition Insufficient gas input.
Poor air-gas adjustment.
Restriction in pilot orifice.
Restriction in main burner ignition port.
Restriction in control valve.
Restriction in gas orifice.
SERVICE
SHUTOFF VALVE
The gas shutoff valve is located to the rear of the range
and is used to shut the range down when gas compo-
nents require servicing. This valve is also used to turn
off all gas to the range when the range is being shut down
for an extended period of time.
Turn off the main gas supply upstream of the shutoff
valve before servicing the valve.
PRESSURE REGULATOR
The pressure regulator is located at the rear of the
range downstream of the shutoff valve. Turn off the main
gas supply upstream of the shutoff valve and pressure
regulator before servicing the pressure regulator, then
remove the shutoff valve and pressure regulator.