BOILER (Fig. 3)
Fig. 3
Pressure Relief Valve
The pressure relief valve located on the top left side prevents pressure in the boiler from exceeding
15 psig.
Manually pull up the lever daily to reduce scale buildup and verify that the pressure relief valve
functions properly.
Gas Valve
Located behind the door. Turn counterclockwise to on; clockwise to off.
Probe Housing Blowdown Valve
Open periodically (monthly) to blow down the probes and remove sediment and scale buildup.
Located toward the back left side, wait until the boiler is cool before opening valve.
Water Inlet Valve
Located toward the bottom center in the boiler, turn the valve off to shut off the water supply.
PL-41514-1
WATER LEVEL GAUGE
MANUAL VALVES
WATER INLET VALVE
GAS VALVE
PROBE HOUSING
BLOWDOWN VALVE
PRESSURE RELIEF VALVE