Specifications

– 5 –
VG30, VG40, VE30 & VE40 BRAISING PANS
The installation location must allow adequate clearances for servicing and proper operation.
Recommended clearances are 24" (61 cm) on the sides and back (for servicing), and 36" (91 cm) on
the front.
The braising pan must be installed so that the flow of combustion and ventilation air will not be
obstructed. Adequate clearance for air openings into the combustion chamber must be provided. Make
sure there is an adequate supply of air in the room suitable for the amount of combustion gas feeding
the braising pan burners.
Do not permit fans to blow directly at the braising pan. Wherever possible, avoid open windows next
to the braising pan. Avoid wall-type fans which create air cross currents within the room.
Gas-Powered Braising Pans Equipped with Casters (Optional)
If casters are assembled to the braising pan, the installation must be made using:
1. A connector (not supplied by Vulcan) that complies with the Standard for
Connectors for
Movable
Gas Appliances
, ANSI Z21.69 (latest edition) or
Connectors for Moveable Gas Appliances
, CAN/
CGA-6.16 (latest edition).
2. A quick-disconnect device that complies with the Standard for
Quick-Disconnect Devices for
Use With Gas Fuel
, ANSI Z21.41 or
Quick-Disconnect Devices for Use with Gas Fuel
,
CAN1-
6.9 (latest edition).
Adequate means must be provided to limit the movement of the appliance, without depending on the
connector and/or any quick-disconnect device or its associated piping to limit braising pan movement.
Attach the restraint at the rear of the braising pan (Fig. 1). If disconnection of the restraint is necessary,
turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply
on and prior to returning the braising pan to its originally installed position.
Electric-Powered Braising Pans Equipped with Casters (Optional)
If casters are assembled to the braising pan, the appliance shall be installed using flexible conduit.
Safety standards require that, when a electric Braising Pan electric supply line is properly connected
to the electrical power supply, an adequate means must be provided to limit movement of the appliance
without depending on or transmitting stress to the electrical conduit.
Fig. 1
If disconnection of the restraint is necessary, turn off the gas and/or electric supplies before
disconnection. Reconnect this restraint prior to turning the gas and/or electric supplies on and prior
to returning the braising pan to its originally installed position.
HOLES PROVIDED
FOR RESTRAINT
PL-56652