Specifications
– 23 –
VG30, VG40, VE30 & VE40 BRAISING PANS
TROUBLESHOOTING
GAS HEAT BRAISING PANS
Problem Possible Cause
Burners do not come on. 1. The power is off or unit is unplugged.
2. The gas supply to the braising pan is off.
3. The thermostat is not set.
4. The internal gas combine valve is off.
5. The pan is not in the lowest position.
6.
Problem with the gas control system. Contact your Vulcan-
Hart authorized servicer.
Burners have yellow flame. 1. Braising pan frame is not level.
2. Wrong gas supply
type (contact plumber or building
maintenance).
3. Incorrect pressure at supply.
ELECTRIC HEAT BRAISING PANS
Problem Possible Cause
Heating elements do not come 1. The power supply is off.
on. 2. The thermostat is not set.
3. Blown fuse in field electrical box.
4. Pan is not in the lowest position.
5. Problem with the control circuits. Contact your Vulcan-Hart
authorized servicer.