Specifications

PL-526441
3 PHASE 240 VOLT RECEPTACLE
Fig. 2
ELECTRICAL DATA
Model Voltage Phase Cycles Max. Power
Max.
Current
Typical
Power
Typical
Current
Breaker
Size
NEMA
Receptacle
VFB12 208/240 1 60 11.9 kW 56 A 9 kW 43 A 60 A 14-60R
VFB12 208/240 3 60 11.9 kW 35 A 9 kW 27 A 40 A* 15-50
*50A if cord connected.
START-UP TESTING
After the oven is connected to the supply circuit, perform the following tests to ensure that the oven is operating properly.
Lamp Test
Turn the oven on by pressing the ON/OFF button. After a few seconds, the display will settle on Recipe 1. At this point, hold
down the 1 button and push the 8 button at the same time. The display will appear as follows:
Would You Like To
Check The Lamps
1 =Yes
2= No
-6-