Boiler User Manual
Broiler Control Valve  — Regulates the flow of gas to the broiler burner. To 
operate the valve, turn it counterclockwise. Turn 
the knob clockwise to the OFF position to shut 
burners down. 
Grease Collector Handle  — The grease pan must be checked frequently and 
emptied when it is about 3/4 full. To check or 
empty the grease collector pan, pull the grease 
collector handle straight out until the pan is 
partially exposed. If the grease pan is being 
emptied, carefully remove the grease pan 
completely from the broiler. Dispose of the grease 
and return the pan to the broiler before continuing 
to broil. 
 Main Gas Valve  — When opened, allows gas to flow to the left and 
right burner and pilots. To open the valve, turn the 
knob counterclockwise. To close, turn the knob 
clockwise. 
BEFORE FIRST USE 
Burn off protective grid oils before cooking food products. With grid in full-up position, operate 
broiler at full output for approximately 1 hour or until smoking stops. The burning will cause a 
somewhat unpleasant odor; this is normal. 
– 12 – 
Broiler 
Control 
Valves 
Grease
Collector
Handle 
Main 
Gas 
Valve 