Service manual
– 12 –
8. Remove the high limit bulb from the tank
mounting brackets.
9. Reverse procedures to install new high limit.
NOTE: When installing a new high limit, take care not
to kink the capillary.
BURNER NOZZLE AND ORIFICE
WARNING: DISCONNECT (UNPLUG) ELECTRICAL
POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING YOU ARE
WORKING ON THE CIRCUIT.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
1. Remove the burners as outlined under Gas
Burners.
2. Hold the burner nozzle with channel locks
and remove the orifice.
3. With channel locks remove the burner nozzle.
4. Reverse procedure to install new burner nozzle
and orifice.