Service manual
– 6 –
F-25114 Rev.A (07-03)
SPECIFICATIONS
Electrical
• 120VAC supply. A 24VAC transformer provides
power for the fryer controls, basket lift controls (if
installed) and the filtering controls on
Kleenscreen™ battery fryers.
• Kleenscreen filter models require a separate
120VAC connection for the filter pump motor (5
amp draw).
Gas Pressures
Manifold (per fryer section):
• Natural - 4" W.C.
• Propane - 10" W.C.
Building supply pressure (Min):
• Natural - 5" W.C. (7" W.C. battery units)
• Propane - 11" W.C. (12" W.C. battery units)
NOTE: Propane or Natural gases -14" W .C. (Max).
TOOLS
Standard
• Standard set of hand tools.
• VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of 20,000
ohms per volt can be used.
• Temperature tester (thermocouple type).
• U-Tube Manometer.
Special
• Field service grounding kit P/N TL- 84919.
• Loctite 242 P/N 520228 or equivalent.
• Burndy pin extraction tool RX2025 GE1; Newark
Electronics Catalog Number 16F6666. Used for
removing pin terminals on Burndy connectors.
Input BTU Rating
GR SERIES
NO. OF
BTU/HR/SECTION
TUBES
GRD25 2 60,000
GRD35, GRC35 3 90,000
GRD45, GRC45 4 120,000
GRD65, GRC65 5 150,000
GRD85, GRC85 5 150,000
GR SERIES GAS FRYERS - GENERAL