Service manual

ER SERIES ELECTRIC FRYERS - GENERAL
F35613 (September 2003) Page 6 of 48
SPECIFICATIONS
MODEL
KW
PER FRYER
SECTION
2
AMPS - EACH FRYER
SECTION
(3 PHASE/ 60HZ)
1
PER LINE
208V 240V 480V
ERD50,
ERD50F
14 39 34 17
17 47 41 20
ERD85,
ERD85F
24 67 58 29
ERC50,
ERC50F
14 39 34 17
17 47 41 20
ERC85,
ERC85F
24 67 58 29
NOTES:
1. Amperage values in the table are
nominal. Tolerance is +5/-10%.
2. 14kw is standard on all fryers except
85 lb. models which are 24kw.
Single Floor Model Fryers
Fryers with the Filter-Ready option installed,
use a 120VAC power cord for the Mobile Filter.
208VAC, 240VAC or 480VAC (3 phase, 60HZ)
to power the heating elements.
Kleenscreen Filtering System
Separate electrical connections are required for
each
section of the battery.
208VAC, 240VAC or 480VAC (3 phase, 60HZ)
to power the heating elements.
On 208VAC and 240VAC models, a
transformer provides power for the fryer
controls, basket lift(s) if installed, and
Kleenscreen filtering controls.
On 480VAC models, a 120VAC connection is
required for each fryer section.
All models require a separate 120VAC
connection for the pump motor (5.0 amp draw).
TOOLS
Standard
Standard set of hand tools.
VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of
20,000 ohms per volt can be used.
Temperature tester (thermocouple type).
Special
Field service grounding kit P/N TL- 84919.
Loctite 242 P/N 520228 or equivalent.
Burndy pin extraction tool RX2025 GE1;
Newark Electronics Catalog Number 16F6666.
Used for removing pin terminals on Burndy
connectors.