Service manual
PN6330663
INSTALLATION AND SERVICE MANUAL
SPACESAVER ELECTRIC BOOSTER HOT WATER
HEATERS
MAKE DISHWASHING CLEANER, SAFER
AND MORE EFFICIENT
4 kW to 54 kW, 208 Vac to 600 Vac, Single or Three Phase
180ºF instantaneous hot water for commercial dishwashers
Suitable for installation with all “name-brand” dishwashers
WARNING
Risk of electric shock. This unit may be connected to more than one
electrical circuit. Turn off all electrical supply circuits before servicing.
IMPORTANT
• The booster heater must be installed in accordance with all local codes.
• This manual must be left with owner and should be hung adjacent to the
booster heater for reference.
• Ensure booster heater is full of water before turning on electricity.
Elements will burn out immediately without water in the booster heater.
• Booster heater voltage must be correct for voltage available. Check
nameplate on the booster heater for full information.
• Overcurrent protection between the power supply and the booster heater
must be provided in accordance with the related code.
• Always ensure power switch is turned off before servicing.
• Under no circumstances should any electrical wiring or internal controls be
touched, except by a qualified electrician or any heating system be
adjusted, except by a qualified service technician.
Post these instructions in a visible place.
DATE OF INSTALLATION :
INSTALLED BY :
PHONE :
Manufactured by
Allied Engineering Company
Division of E-Z-Rect Manufacturing Ltd.
Manufacturers of Gas and Electric Boilers, Heat Exchangers, Electric Boosters, Indirect Tanks
94 Riverside Drive, North Vancouver, B.C. V7H 2M6 • Telephone 604-929-1214 • www.alliedboilers.com
Branches: Calgary • Edmonton • Toronto • Denver
(
OPTIONAL
)