Griddle User Manual
- 
13 - 
PILOT LIGHTING PROCEDURE- MSA AND ASA MODELS 
1. Turn the main gas shut-off valve to the OFF position. Wait 5 minutes to allow 
 any gas that may have accumulated in the burner compartment to escape. 
2. Turn the main gas shut-off valve ON. 
3. Depress and hold the safety valve button while lighting the corresponding pilot. You will have to 
 reach under the front of the unit to light with an outside ignition source(such as a lit taper, etc.) while 
 viewing thru the pilot sight hole. 
4. When the gas at the pilot has been burning for about 45 seconds, release the safety valve button. 
 If the pilot does not remain lit, repeat the operation allowing more time before releasing the button. 
 The amount of time necessary to hold the safety valve button will increase at the initial installation of 
 the unit and if the main gas supply has been turned off for a long period of time. It may be 
 necessary to adjust the pilot valve to increase gas to the pilot. 
5. Repeat steps until all pilots are lit. 
6. If after completing steps 1-5 pilot does not light, turn off the main gas shut-off valve and contact an 
 authorized service agency. 
CUTAWAY VIEW 
pilot burner 
pilot cutout 
 12” 
pilot safety
valve button 
pilot sight 
hole
Fig. 12 