Specifications

— 14 —
ELECTRICAL CONNECTIONS (CONVECTION OVEN MODELS [90 SERIES] ONLY)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE
PROVIDED WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG
BE CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO
NOT REMOVE THE GROUNDING PRONG FROM THIS PLUG.
The range is designed for 120 volt power supply or an optional 240 volt single-phase 15 Amp power
supply.
All 120 volt ranges are supplied with a flexible electric supply cord and plug and must be plugged into
the proper receptacle before turning on gas. If the appliance is not equipped with a grounding plug and
electric supply is needed, ground the appliance by using the ground lug provided. All 240 volt electric
systems are manufactured for hard wire installation connections. (Refer to the wiring diagram inserted
into this manual.) An electrical diagram is attached to the back near the motor mounting area.
Do not connect the range to electrical supply until after gas connections have been made.