The specifications in this area are open according to the supplier's own style. However,
it is to be taken into consideration, the good design and form, lighting, air-
conditioning, heavy duty capacity to bear the work pressure and patient numbers.
The specifications required for the containers:
1. Possibility to transport by ****C.-130 transport aircraft .
2. Possibility of all containers to be transported by ships.
3. Possibility of all containers to be borne or towed by trucks.
4. Trailers must have characteristics of robustness, durability, ease of movement,
endurance of movement, shaking and shocks.
5. Trailer shall bear the harsh climatic conditions and temperatures and shall be
compatible with military standards.
6. The trailer shall be thermally insulated with nonpoisonous strong and fire-
resisting internationally approved material.
7. The x-ray trailer shall be insulated with lead according to standard specifications.
8. Trailer weight shall be suitable not exceeding in any case 6 tons when empty and
not exceeding 10 tons with full load and contents.
9. Easy dismantling, deployment, use and application.
10. Sufficient and properly insulated doors and windows with taking in consideration
the future need for additional doors in case of connecting containers to form a
closed hospital.
11. Sufficient electrical fittings and numbers of sockets for medical systems. The
available voltage must meet the technical requirements of the equipment and be
of internationally recognized medical installation quality.
12. Sufficient, proper, easy to install and service lighting inside trailer. In addition
the lighting in the operations and intensive care rooms shall be of washable and
sterilizable type.
13. The Trailer shall have all necessary non medical necessary connections (such as
electricity, water and sanitary drainage networks).
14. The Trailer shall have all the necessary medical extensions (such as oxygen
network, compressed air...etc.), and their locations inside the trailer shall be
compatible with their purpose
15. The Trailer shall have AUTO STEAL FOOT hydraulic lifting and lowering
system for each container, fixed at each of the four container corners, raised from
the ground by a distance minimum ½ meter.
Field hospital specifications (trailed - borne)
(continued)
16. Electricity and water inlets on the outside walls of the Trailer shall be weather
proof.
17. Operation and intensive care rooms shall be provided with filters for bacteria and
negative pressures.
18. All trailers operate with hydraulic extension systems and in case such a system