INSTALLATION & OPERATIONAL MANUAL 1GRA & GRAF SERIES GAS FRYERS VFRY18 & VFRY18F HDR FRYERS With KleenScreen PLUS® Filtration Systems MODELS: 1GR45A Shown - Solid State Control Secured Behind the Door VFRY18 1GR45A 1GR65A 1GR85A 1GR45AF 1GR65AF 1GR85AF 2GR45AF 3GR45AF 4GR45AF 2GR65AF 3GR65AF 2GR85AF 3GR85AF VFRY18 VFRY18F ML-136647 ML-136648 ML-136649 ML-136798 ML-136795 ML-136796 ML-136650 ML-136653 ML-136656 ML-136651 ML-136654 ML-136652 ML-136655 For additional information on Vulcan-Hart or to locat
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS………………………………………………… 4 FRYER CAPACITIES………………………………………………. 4 UNPACKING………………………………………………………… 4 INSTALLATION………………………………………………………...…… 5 Clearances…………………………………………………... 6 Location ………………..……………………………….…. 6 CODES AND STANDARDS……………………………………….. 6 ASSEMBLY …………..
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS INTRODUCTION GENERAL Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance. Before installing the fryer, thoroughly read this manual and carefully follow all instruction. This manual is applicable to model listed on the cover page. Procedures in this manual will apply to all models unless specified.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Check that the following have been included: Crumb Rack(s) Basket Hanger(s) Tank Brush Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer Batteries with the KleenScreen PLUS® Filtration System have casters installed from the factory. Drain Pipe Extension for freestanding fryers only. Twin Fry Baskets (2) per fry tank Cleanout Rod for freestanding fryers only. Crumb Scoop for freestanding fryers only.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Clearances: Minimum clearance from combustible construction: 6” (15 cm) from the sides of the fryer 6” (15 cm) from the back of the fryer The fryer may be installed on combustible floors. Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA. 02169-7471. In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of exhaust shall comply with 248 CMR. In Canada: Local codes CAN/CSA-B149.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS GAS CONNECTION All gas supply connections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single units and 1-1/4” (31.75 mm) for batteries.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The restraining device should be attached to the cutout on the back panel. See illustration for location. In Australia, use only the caster supplied by the manufacturer for the fryer device.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. Electrical diagram located on inside of door. LEVELING THE FRYER Check the level of the fryer by placing a level on top of the fryer after gas connections have been made. Ensure that the fryer is level front-to-back and side-to-side in the final installed position. If using casters, lock the wheels after unit is level.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Rinse fryer and accessories thoroughly and drain the fryer. Wipe tank completely dry with a soft, clean cloth. FILLING TANK WITH SHORTENING Close the drain valve. Fill the fryer tank with shortening. Vulcan recommends using liquid shortening. Shortening level should be between the MIN and MAX lines in the fryer tank. Shortening will expand when heated. Do not fill the fryer tank past the MAX line.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Fry Basket Guidelines Do not overfill baskets. (See fry basket capacity below) Carefully lower basket into oil. When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter covered foods should be dropped carefully, one by one, into shortening or basket.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Solid State Knob Control Indicator Lights (On/Start/Heating) Temperature Knob Control Melt Switch Power Switch Filter Switch (For those models with KleenScreen PLUS® Filter Systems) Start Button TURNING ON THE FRYER Open the door to the fryer. Select Liquid or Solid Shortening pressing the switch to the desired selection. Set temperature by turning the knob to the desired temperature. Press the power switch to the ON position.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS EXTENDED SHUTDOWN 1. Open the door to the fryer. Press the power switch to the OFF position. 2. Thoroughly drain the fryer. Refer to DRAINING THE FRYER. 3. Clean the fryer according to CLEANING. 4. Turn off the main gas shutoff valve. FILTERING THE OIL Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer. Filter shortening at least once a day. 1. A cold fryer will not drain properly.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS DRAINING THE TANK 1. Open the door to the fryer. The power must remain ON for the fryer to filter correctly. 2. Insert the drain extension into the drain valve. Tighten only hand tight. 3. Direct the drain spout into the container that you want to drain the shortening into. 4. Open the drain valve slowly allowing the oil to drain into the container. When the container is full or the fryer tank is empty, close the drain valve.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS 10. Close the drain valve and add shortening. Follow the FILLING TANK WITH SHORTENING procedure in this manual. The fryer is now ready for use. Press the start button to begin heating the shortening. CLEANING Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer. Daily Clean your fryer regularly with the tank brush along with a damp cloth, and polish with a soft dry cloth.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS KleenScreen Plus® Filtration System Installation and Operational Manual for “AF” Models 2GR45AF Shown GAS KleenScreen PLUS® Models: 1GR45AF 1GR65AF 1GR85AF 2GR45AF 3GR45AF 4GR45AF 2GR65AF 3GR65AF 2GR85AF 3GR85AF VFRY18F ML-136798 ML-136795 ML-136796 ML-136650 ML-136653 ML-136656 ML-136651 ML-136654 ML-136652 ML-136655 VULCAN-HART F-32934 Rev.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Filtering Instructions for KleenScreen PLUS® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both tanks be drained at the same time. Assembly After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure you remove the insert located inside the filter screen.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Fully assembled filter screen assembly: Fig. 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube Fabric Envelope Insert (Different from Screen Assembly) Fabric Envelope Closing Clip Same Knurled Knob Fig. 4 VULCAN-HART F-32934 Rev.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE). Step 1 Discard all oil from the filter vessel, (see pages 23 or 24). When the filter pan is empty, use a spatula and scrape off all debris left on the filter envelope and in the filter pan.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. Never run water or boil out solution through filter and motor / pump. Doing so will void your fryer warranty. FILTERING PROCEDURE Oil Temperature should be 300-350° F (149-177°C).
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the return line to run back into the filter pan. This will take about 30 seconds to complete. Then open the drawer completely to clean filter components. REMOVING EXCESS DEBRIS FROM THE SCREEN FILTER: 1. Pull the filter drawer out and remove the crumb basket and empty any debris into the trash. 2. Remove the filter screen assembly. Scrape debris from the filter screen.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drain extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor / pump. Drain the boil out solution into a bucket or place a hose on the end of the drain extension allowing the other end to flow into a floor drain. In Fig. 6 the arrow is pointing to the drain extension.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer. Spilling hot fryer compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. FLUE VENT INSPECTION When the fryer is cool, inspect annually. Check the flue and clear any obstructions. Service in the US and Canada Contact you local Vulcan-Hart Service office or address on the front of this manual.