Specifications
GRM SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. N (June 2013)
-16-
5. Set the temperature knob to 200°F or for the recommended solution being used.
Allow solution to simmer for about 15 to 20 minutes.
6. Drain the cleaning solution from the tank.
7. Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to
neutralize alkaline left by the cleaner. Solution level must be between the MIN and
MAX level on the fryer tank.
8. Bring the solution to a simmer only, turn the thermostat off. Allow to stand for a few
minutes.
9. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear,
hot water. All traces of cleaner must be removed. Dry the tank thoroughly.
10. Close the drain valve and add shortening. Follow the FILLING TANK WITH
SHORTENING procedure in this manual. The fryer is now ready for use.
KleenScreen PLUS® Filtration System
Installation and Operational Manual
For GRMF Models
2GR45MF ML-136417
2GR65MF ML-136418
2GR85MF ML-136419
3GR45MF ML-136420
3GR65MF ML-136421
3GR85MF ML-136422
4GR45MF ML-136423