SDS

珠海光宇电池有限公司
ZHU HAI COSLIGHT BATTERY Co.,Ltd
No.209,Zhufeng Way,Xinqing Science & Technology Park,Doumen District,Zhuhai519180, P.R.China
珠海市斗门区新青科技工业园珠峰大道209
Tel:86-756- 6199908 Fax:86-756-6199910 http://www.coslight.com.cn
4.244
4.244
4.244
4.244
T1
Altitude
Simulation
Passed
T2 Thermal Test Passed
T3 Vibration Passed
T4 Shock Passed
T5
External
Short circuit
Passed
T6 Impact Passed
T7 Overcharge Passed
Battery
only
T8
Forced
Discharge
Passed
Cell
only
Diethyl Carbonate
(CAS#105-58-8)
Propylene Carbonate
(CAS#108-32-7)
None established None established
Dimethyl Carbonate
(CAS#616-38-6)
None established None established
There are being tested in accordance with the UN Model Regulation,Manual of Test and Criteria,Part III,subsection 38.3.
Ethyl Methyl Carbonate
(CAS#623-53-0)
No mass loss, leakage, venting, disassembly, rupture, and fire, OCV should
not be less than 90% before testing
None established None established
SECTION 3-Independent Certification of Lithium-Ion cell Transportation Model Regulation
None established None established
No mass loss, leakage, venting, disassembly, rupture, and fire, OCV should
not be less than 90% before testing
No disassembly and fire within seven days of this test
No mass loss, leakage, venting, disassembly, rupture, and fire, OCV should
not be less than 90% before testing
External temperature should not exceed 170 degree, No disassembly,
rupture, and fire within six hours of this test
External temperature should not exceed 170 degree, No disassembly and
fire within six hours of this test
No disassembly and fire within seven days of this test
SECTION 4-HAZARDS IDENTIFICATION
All chemical materials of lithium cell are shorted in a hermetically sealed metal case, designed to withstand and pressures
encountered during normal use. There is no physical danger of ignition or explosion and chemical danger of hazardous
material's leakage during normal use. However, if exposed to a fire, added mechanical shocks, decomposed, added electirc
stress by miss-use, the gas release vent will be operated and hazardous materials may be released.
Potential Health Effects:
Cobalt and Cobalt compounds are considered to be possible human carcinogen(s). These chemicals may cause allergic skin
sensitization(rash) and irritate eyes, skin, nose, throat, respiratory system.
No mass loss, leakage, venting, disassembly, rupture, and fire, OCV should
not be less than 90% before testing
第 2 页,共 5 页