TECHNICAL SPECIFICATIONS
Printing
Printing method: Impact. Paper feed: Sprocket. Character matrix: 6 dot or 8 dot.
Character set: USA default (8 total). Printing direction: Bidirectional. Paper width:
Adjustable (1.5 to 15 inches). Page length: Selectable (3.0 to 14 inches). Paper
weight: 20 lb. to 100 lb. Text buffer: 18,000 characters.
Default spacing (Library of Congress): Dot spacing: Alpha 0.090 inch, Graphics 0.080
inch. Dot Height: 0.020 inch. Character spacing: 0.240 inch. Line spacing: 6 dot 0.400
inch, 8 dot 0.490 inch. Other spacing formats selectable: Regular (Library of
Congress), California sign, Jumbo, Regular with relaxed line spacing, Petite
(Japanese), and Petite with relaxed line spacing for interline printing.
Thomas: Printing speed: Single-sided 40 characters per second, 40 characters per
line. Line width in Library of Congress spacing: Alpha 40 characters (maximum).
Graphic 60 characters (120 Dots maximum)
ET or Juliet PRO 60: Printing speed: Interpoint 60 characters per second at 40
characters per line. Single-sided 35 characters per second at 40 characters per line.
Line width in Library of Congress spacing: Alpha 40 characters (maximum). Graphic
60 characters (120 dots maximum).
Juliet Classic or Juliet Pro: Printing speed: Interpoint 55 characters per second at
56 characters per line, 42 characters per second at 42 characters per line.
Single-sided 40 characters per second at 56 characters per line, 30 characters per
second at 42 characters per line. Line width in Library of Congress spacing: Alpha 56
characters (maximum). Graphic 80 characters (160 Dots maximum).
Actual printing speeds may vary based on paper grade setting, page layout and data
format.
Physical Description
Width: 24.63 inches (62.6 cm). Depth: 11.5 inches (29.2 cm). Height: 8.63 inches
(21.9 cm). Weight: 51 pounds (23.6 kg). Case Style: Desktop. Sound Level: 68 dba
average. Sound level may vary with ambient conditions.
Environmental
Temperature: Operating or Storage 35 F to 100 F (2 C to 37.8 C). Humidity:
Operating or Storage 10% to 95% (noncondensing).
Electrical
Line voltage: USA 105 to 125 VAC. EURO 210 to 250 VAC. Amperage: USA 2.0 Amp
Average. EURO 1.0 Amp Average. Fuse size: 250V, 1.6A T(slow-blow). Watts:
Approximately 120.