Specifications

22 Chapter 1: Introduction
on the video data (sync on green). Otherwise, you must use the Matrox
DVI-TO-8BNC/O cable or a custom cable that re-routes the synchronization
signals to the appropriate pins.
If needed, you can purchase a Camera Link or PoCL Camera Link cable from the
video source manufacturer, 3M Interconnect Solutions for Factory Automation,
Intercon 1, or other third parties.
SOLCLBACCxxPAK accessory kit, which allows you to replace the DBHD-15
auxiliary I/O connector on Matrox Solios eCL/XCL-B with a DB-9 connector.
In this case, the DB-9 connector has the same pinout as auxiliary I/O connector 1
(DB-9) on the adapter board of other Matrox Solios eCL/XCL boards. Note
however, when using the optional DB-9 connector, some DBHD-15 signals are
not available.
Handling components
The electronic circuits in your computer and the circuits on Matrox Solios are
sensitive to static electricity and surges. Improper handling can seriously damage
the circuits. Be sure to drain static electricity from your body by touching a metal
fixture (or ground) before you touch any electronic component. In addition, do
not let your clothing come in contact with the circuit boards or components.
Warning Before you add or remove devices from your computer, always turn off the power
to your computer and all peripherals.
Installation
The installation procedure consists of the following steps:
1. Complete the hardware installation as described in Chapter 2: Hardware
installation.
2. Complete the software installation procedure described in the documentation
accompanying your software package.
More information For information on using multiple Matrox Solios boards, refer to Chapter 3: Using
multiple Matrox Solios boards.