Specifications
Connectors on Matrox Solios eCL/XCL dual-Base/single-Medium and eCL/XCL-F boards 123
When the board is configured in single-Medium or single-Full mode, the first
connector has the pinout described above, while the second connector has the
following pinout.
To interface with the above connectors, use a standard Camera Link cable. You
can purchase such a cable from your video source manufacturer, 3M Interconnect
Solutions for Factory Automation, Intercon 1, or other third parties. Note that
this cable is not available from Matrox.
❖ If using both Camera Link connectors to connect to the same video source
(single-Medium mode or single-Full mode), the cables you choose must be of the
same type and length. Otherwise, the cables can have different propagation delays.
Pin Hardware signal name Description
1 Inner shield Ground (inner shield), or +12V to camera in PoCL mode.
2+,15- Z3
Video input data Z3.
*
*. When the board is configured in single-Medium mode, these pins are reserved.
3+,16- Zclk+
Clock input Z.
*
4+,17- Z2
Video input data Z2.
*
5+,18- Z1
Video input data Z1.
*
6+,19- Z0
Video input data Z0.
*
7terminated
Unused.
*
8+,21- Y3 Video input data Y3.
9+,22- Yclk Clock input Y.
10+,23- Y2 Video input data Y2.
11+,24- Y1 Video input data Y1.
12+,25- Y0 Video input data Y0.
13 Inner shield Ground.
14 Inner shield Ground.
20 100 Ω
Unused.
*