Specifications
112 Appendix B: Technical information
Output
signals in
LVDS format
On the analog video input (DVI) connectors:
•No termination.
• Output current (loaded 100 Ohm): 3.1 mA (typ).
• Output voltage (loaded 100 Ohm):
- differential: 250 mV (min) to 450 mV (max).
- common-mode: 1.125 V (min) to 1.375 V (max).
- low of 1.02 V (typ), 0.9 V (min); high of 1.33 V (typ), 1.6 V (max).
On external auxiliary I/O connector 0:
• Output current (loaded 100 Ohm): 26 mA total (typ).
• Output voltage (loaded 100 Ohm):
- differential: 250 mV (min), 450 mV (max).
- common-mode: 1.125 V (min), 1.375 V (max).
Input signals
in TTL format
On the analog video input (DVI) connectors, for all TTL input signals, except for TTL auxiliary signals that can be configured for
trigger input:
•No termination.
• Clamped to 4 V (max source current +100 mA).
• Input current: 5 μA (max).
• Input voltage threshold: low of 0.8 V (max); high of 2.0 V (min).
On the analog video input (DVI) connectors, only for TTL auxiliary signals that can be configured for trigger input:
• No series termination.
• Pulled up to 5 V with 4.7 k Ohm.
• Clamped to -0.7 V and to 5.7 V.
• Input current: 1 μA (max).
• Input voltage threshold: low of 0.8 V (max); high of 2.0 V (min).
On external auxiliary I/O connector 0:
•No termination.
• Clamped to -0.7 V and to 4.0 V.
• Input current: 1 μA (max).
• Input voltage threshold: low of 0.8 V (max); high of 2.0 V (min).
Matrox Solios eA (starting from version 100)/Matrox Solios XA (starting from version 200)