Specifications

17
PASSWORD
Instructions for using the Password feature with the 5200 controller.
#1 is the PASSWORD screen. This screen has 3 items: Password Table, Lock System, Unlock System.
Password Table:
Passwords and access levels are set in this table. There are (8) eight available passwords, with the user
levels between 1 (being the highest security) and 3 (being the lowest security). Each password must be (8)
eight characters long to be valid. It is very important to change the user level of any unused password to the
lowest setting to avoid unauthorized personnel to have total access of the system.
To enter password: Click on the (8) eight-digit numbers, enter new number, press ENT key
Repeat the process for entering the user level number.
Lock System:
This button will enable the password feature. Any screen requiring a password will prompt the user before
allowing access to the screen. After enabling passwords the following conditions will exist.
Level 3 access: Screens available to a user with level 3
access is RUN, PASSWOD, and the first
screen of SYSTEM
Level 2 access: Screens available to a user with level 2
are RUN, RECIPE, TOTALS, EMPTY
MATERIAL, ALARM, PASSWORD,
and the first and second screens of SYSTEM
Level 1 access: Screens available to a user with level 1
access is RUN, RECIPE, TOTALS,
SETUP, EMPTY MATERIAL, ALARM
PASSWORD, and all screens of SYSTEM
On the third SYSTEM screen the options to Default to Factory Settings and Exit to System. In order to Exit
to System the default password set at the factory must be entered; the Exit to System button pressed to verify
the password. This password should not be available to any unauthorized personnel. The default value is
preset at 1973.
Unlock System:
This button is used to activate the different user levels. For example, you need to unlock all features
available to someone with level 2 access. First, press Unlock System button, enter password, press enter.
Now all level 2 screens are unlocked. Please note, that in order to lock the system to the highest security
level 1, the Lock System button must be pressed. If not, and someone with level 1 access inadvertently
forgot to press the Lock System button this would make all screens available to everyone. Please note, only
someone with level 1 access can enter the Password Table screen after Lock System is enabled.