MAXIMUM TARE WEIGHT EXCEEDED ALARM:
TOO MUCH BLENDER VIBRATION ALARM:
BAD FEEDER / JAMMED OR CLOSED CHUTE ALARM:
At the start of running each Recipe Batch, the WBC checks the current Tare Weight and compares it to the initial Run
Tare Weight. If the current Tare Weight is more than 25% of the Weigh Chamber size, greater than the initial Tare
Weight, this Alarm message will be displayed.
The WBC will stop running until the RUN or STOP Key is pressed.
If the RUN Key is pressed, the Alarm is ignored, the Alarm Output contacts open, and the WBC will continue
running.
If the STOP Key is pushed, the WBC will stop running.
This Alarm is NOT logged.
At the start of each Batch Fill Cycle, the WBC first checks the Load Cell weight reading for 3 seconds. If the reading
varies too much (probably due to too much Blender vibration), the WBC will show this Alarm message.
If the RUN Key is pressed, the WBC will try to start running the process again.
If the STOP Key is pressed, the WBC will stop.
This Alarm is NOT logged.
A L A R M S
FEEDER #x PROBLEM
FIX Then Press RUN
If a Recipe can NOT be completed from a Bin (i.e. running the Bin’s vibratory feeder for 15 seconds with no weight
change) and the Bin’s Low Level sensor is OFF, then show this Alarm message, close the Alarm Output contacts,
and stop the weigh chamber Fill Cycle.
If the ALARM ACK Key is pressed, open the Alarm Output contacts only.
If the RUN Key is pressed, open the Alarm Output contacts, turn ON the vibratory feeder and try running the
process again.
Top Line Flashes