User`s guide

Accessing the Central Management Utility
3-4
5100-A2-GB20-00
November 1996
Setting the Terminal Interface Options
The terminal interface options of the terminal-based central management utility
are set in the c:\HOTWIRE\hotwire.ini file. If you want to change any of the
options, use the following procedure.
" Procedure
1. Make a backup copy of the hotwire.ini file in case the file becomes
corrupted during editing, i.e., copy hotwire.ini hotwire.bak.
2. Edit the file with any ASCII text editor using the information provided in the
following table.
Parameter
Description
Baud Rate Sets the communications rate. Possible values:
H 9600
H 19200 (default)
Port Name Sets the COM port. Possible values:
H COM1
H COM2
H NONE (default)
Selecting NONE disables the central management
utility when accessed from the serial port.
Flow Control Sets the flow control protocol. Possible values:
H XON_XOFF (default)
H DTR_DSR
H RTS_CTS
H NONE
Select NONE (all uppercase) if your terminal does not
support any of the protocols listed.
If you choose DTR_DSR, make sure that your
terminal is connected and powered on to avoid
hanging the CO PC.