User`s guide

Installing and Connecting the Card
2-9
5100-A2-GB20-00
November 1996
Always connect the CO switch tip and ring leads to the bottom two
A-column pins of a four-row set: A3(tip)–A4(ring), A7(tip)–A8(ring),
A11(tip)–A12(ring), and so on.
Always connect the subscriber loop tip and ring leads to the top two
D-column pairs: D1(tip)–D2(ring), D5(tip)–D6(ring), D9(tip)–D10(ring),
and so on.
4. Plug the end of an 8-pin modular cable into the J2 network access connector
of a CO card.
5. Plug the other end of the cable into the appropriate DSL connector of the
multi-pin block (Connector #1 in the figure on page 2-8).
6. Connect the tip lead of the CO switch pair to the appropriate pin of the
multi-pin block (A3 in the figure on page 2-8).
7. Connect the ring lead of the CO switch line to the appropriate pin of the
multi-pin block (A4 in the figure on page 2-8).
8. Connect the tip lead of the subscriber loop to the appropriate pin of the
multi-pin block (D1 in the figure on page 2-8).
9. Connect the ring lead of the subscriber loop to the appropriate pin of the
multi-pin block (D2 in the figure on page 2-8).
10. Jumper pins B to pins C using bridge clips (B1–C1, B2–C2, B3–C3, B4–C4 in
the figure below).
If you are using POTS monitoring bridge clips, place them on B3–C3 or
B4–C4.
A
B and C
(with Bridge Clip)
D
496-15023
1
2
3
4