Installation guide

Acme Packet 6100 Hardware Installation and Maintenance Guide 57
5 Startup
Introduction
This chapter describes Acme Packet 6100 startup which involves two tasks:
Pow
ering on the Acme Packet 6100.
Cre
ating the first console connection to the Acme Packet 6100.
You can perform these actions in any order. However, if your console
con
nection is configured first, you can observe the booting processes as your
Acme Packet 6100 goes online.
The last section of this
chapter explains how to login to your system.
Creating a Console Connection
This section explains how to create a console connection.
Prerequisites In order to create a console connection to the Acme Packet 6100, you must
configure the terminal hardware and software appropriately.
Table 5 - 7. Terminal Application Serial Settings for Use with Console Port
Serial Connection Parameter Setting
Baud Rate 115,200 bps
Date Bits 8
Parity No
Stop Bit 1
Flow Control None
Note: Your terminal application and serial port MUST be capable
of operating at 115.2 Kbps for creating a console session.
Creating a Console
Connection
To create a console connection:
1. Set the terminal application’s parameter
s to match the Acme Packet 6100
default parameters.
2. The Acme Packet 6100 console port is located on the Acme Packet 6100
N
IU. You must connect to the console port when initially booting the Acme
Packet 6100.
3. If the Acme Packet 6100 is already powered on, press the Enter key a few
ti
mes to activate the console connection. When ACLI text is displayed on
the screen, the console connection has been successfully created.