Installation guide
Acme Packet 6100 Hardware Installation and Maintenance Guide 111
Device Ratings This table lists the alarm device ratings of the Acme Packet 6100.
Table 7 - 24. Acme Packet 6100 Device Ratings
Specification Value
AC 100- 240 VAC, 50-60 Hz, 5A (X2)
DC -48 VDC, 10 A (x2)
Environmental Specifications
For the Acme Packet 6100 to function properly, Acme Packet recommends that
you follow the environmental guidelines in the following table.
Table 7 - 25. Acme Packet 6100 Environmental Specifications
Specification Description
Temperature The Acme Packet 6100 is required to operate within the temperature range
of
:
+0° C to +40° C, 32° F to 104° F (operating)
-20° C to +65° C, -4° F to 149° F (storage)
Relative Humidity Operating conditions of 10% to 85% humidity under
non-condensing operat-
ing conditions
Maximum Altitude The Acme Packet 6100 is required to operate below the maximum altitude
of
10,000 feet.
Air Flow 100 CFM
Power Dissipation 250W typical 350W maximum (base syst
em with 2 x 10GbE NIU)
Connector Specifications
Refer to the following table for information about the connector specifications
for the Acme Packet 6100.
Table 7 - 26. Acme Packet 6100 Connector Specifications
Specification Description
AC Connector Port The IEC lead connector port on eac
h power supply accepts a 3-
lead IEC-60320 C14 connector for AC power installations (2)
RJ45/Management Ethernet
Po
rts
The 3 x 8-pin RJ45 10/100/1000BaseT ports are compliant with
IEEE's 802.3, 802.3u, and 802.3ab.
RJ45/Alarm Contact Port Any alarms generated by the system are accessible via the 8-pin
RJ45
alarm contact port.
RS232/Serial Port The RS232 serial port uses an 8-pin RJ45 conn
ector that supports
RS232-C protocol.